Home / LoRaWAN Payload Helper
  • Vicki
  • AQI Sensor
  • HT Sensor
  • Flood Sensor
  • T Valve

Downlink Generator

Send command to device to execute (set)

Possible values: 0 (disabled) and 1 (enabled)

Value should be in minutes

Possible value range: 5C - 30C

Possible values: 0 (unconfirmed) and 1 (confirmed)

Possible values:
0 – Online manual control mode. Default for the device;
1 – Online automatic control mode;
2 – Online automatic control mode with external temperature reading.

Send command to device to receive information (get)

Generated command

Uplink Decoder

Paste your uplink here

Downlink Generator

Send command to device to execute (set)

Value should be in minutes

Possible values: 0 (unconfirmed) and 1 (confirmed)

Volume - 0-min... 14-max, 15-OFF

Frequency - 0-1kHz, 1-1.5kHz ... 10-6kHz

Active Time - in seconds, min-1s,"0"- buzzer stay active until command or button is pressed

On Time - in milliseconds, resolution – 10ms

Off Time - in milliseconds, resolution – 10ms

Behavior - 1-ON, 2-Blink fast, 3-Blink slow, 4-OFF

Duration - in seconds, if it`s 0-until it’s changed from command or button is pressed

Value should be in minutes

Period Confirmen Uplinks must be dividable by device keepalive period + 7

0 for disabled

"pCU" - Period Confirmen Uplinks

"pUU" - Period Unconfirmen Uplinks

"dKP" - Device Keep Alive

Send command to device to receive information (get)

Generated command

Uplink Decoder

Paste your uplink here

Downlink Generator

Send command to device to execute (set)

Value should be in minutes

Possible values: 0 (unconfirmed) and 1 (confirmed)

Value should be in minutes

Period Confirmen Uplinks must be dividable by device keepalive period + 7

0 for disabled

"pCU" - Period Confirmen Uplinks

"pUU" - Period Unconfirmen Uplinks

"dKP" - Device Keep Alive

Send command to device to receive information (get)

Generated command

Uplink Decoder

Paste your uplink here

Downlink Generator

Send command to device to execute (set)

Behavior - 1-ON, 2-Blink fast, 3-Blink slow, 4-OFF

Volume - 0-min... 14-max, 15-OFF

Frequency - 0-1kHz, 1-1.5kHz ... 10-6kHz

Active Time - in seconds, min-1s,"0"- buzzer stay active until command or button is pressed

On Time - in milliseconds, resolution – 10ms

Off Time - in milliseconds, resolution – 10ms

Value should be in seconds. Resolution is 10s

Value should be in minutes

Send command to device to receive information (get)

Generated command

Uplink Decoder

Paste your uplink here

Downlink Generator

Send command to device to execute (set)

Values should be in minutes, range 0-255, cannot be both 0

Led Id - 0-Led Open, 1-Led Close, 2-Led Leakage, 3-Led Flood

Behavior - 1-ON, 2-Blink fast, 3-Blink slow, 4-OFF

Volume - 0-min... 14-max, 15-OFF

Frequency - 0-1kHz, 1-1.5kHz ... 10-6kHz

Active Time - in seconds, min-1s,"0"- buzzer stay active until command or button is pressed

On Time - in milliseconds, resolution – 10ms

Off Time - in milliseconds, resolution – 10ms

Maximum allowable value is 15

Possible values: 0 (disabled) and 1 (enabled)

Value should be in minutes. Default value is 5

Default value for the device is 1850mV

Possible values: 0 (disabled) and 1 (enabled)

Send command to device to receive information (get)

Generated command

Uplink Decoder

Paste your uplink here